Monitoring the interior of high-temperature kilns and furnaces is critical for process optimization, energy efficiency, and safety. However, the extreme heat, heavy dust, and corrosive gases make it nearly impossible for standard industrial cameras to survive. Our Automatic High-Temperature Furnace Camera System is specifically engineered to withstand these harsh environments, providing real-time, high-definition visual access to furnace temperatures of up to 2000℃.
Designed for reliability and operator safety, this system features a fully automatic insertion and retraction mechanism. In the event of a power failure, loss of cooling air/water, or excessive internal temperatures, the fail-safe system automatically retracts the probe to prevent equipment damage.
Extreme Durability: IP68 protection and Explosion-Proof certification (Exd IIC T6 Gb) ensure safe operation in the most demanding and hazardous zones.
Superior Optical Clarity: Equipped with a sapphire heat-resistant lens and a special spiral air curtain design that effectively prevents dust accumulation, ensuring a clear view at all times.
Precision Monitoring: Features a 27x optical zoom (3.6-78mm) and two-color temperature measurement for accurate flame and material observation.
Seamless Integration: Fully compatible with existing plant DCS/PLC systems for remote control of the camera menu, aperture, and real-time alarm monitoring.
Product Introduction | Automatic in-furnace insertion, suitable for all types of high-temperature kilns |
Suitable for furnaces with wall thickness ≤ 500mm | |
Probe cover made of stainless steel for superior corrosion resistance | |
• Special spiral air curtain design prevents dust accumulation on the lens | |
• Advanced air cooling design ensures reliable operation under harsh conditions | |
Sapphire heat-resistant lens | |
Automatic probe insertion and retraction mechanism | |
High-temperature resistant cylinder for long-term reliability | |
• Fail-safe: Probe automatically retracts in case of cooling water/gas or power supply failure | |
• Flexible control: Can be operated remotely from the central control room or locally in the field | |
• Seamless integration: PLC and DCS software can control the camera menu and aperture | |
• Front end adopts high-temperature resistant optical pinhole lens | |
• 27x optical zoom (3.6-78mm) integrated camera | |
Automatic Protection & Retraction Triggers | a. Temperature inside the protective cover exceeds 50℃ |
b. Compressed air input pressure drops below 0.2 MPa | |
c. Probe cover cooling water flow rate drops below 0.2 m³/h | |
d. External power supply is cut off | |
e. Retraction signal triggered from control room or field device | |
f. Alarm signals can be integrated with DCS | |
Technical Parameters | Resolution: 1600 × 1200 |
Focal length: 3.6-78mm (27x optical zoom) | |
Retraction stroke: 550mm | |
Compressed Air | a. Total inlet pipe: G1" |
b. Connection nozzles: 4 × G1/2" (with globe valve) | |
c. Inlet pressure: 0.2 ~ 0.7 MPa | |
d. Inlet temperature: ≤ 35℃ | |
e. Minimum flow: 0.3 m³/min | |
Cooling Water | a. Main intake pipe: G3/4" |
b. Connection ports: 2 × G1/2" (with globe valve) | |
c. Inlet pressure: 0.1 ~ 0.7 MPa | |
d. Minimum flow: 0.8 m³/h | |
e. Inlet temperature: ≤ 35℃ | |
Working Temperature | a. Automatic retraction device: 5℃ ~ 80℃ |
b. Control device: -5℃ ~ 50℃ | |
c. Max. furnace temperature: ≤ 2000℃ | |
Dimensions | a. Automatic retraction device: 1500 × 400 × 305 mm |
b. Field control box: 400 × 500 × 250 mm (W × H × D) | |
c. Control console (3 types available, please specify when ordering): | |
c-1. Wall-mounted installation (see figure) | |
c-2. Desk/Console installation (see figure) | |
c-3. Cabinet-mounted or tabletop placement (see figure) | |
d. Installation diagram (see figure) | |
e. For wall opening requirements, please refer to the installation drawing. | |
Protection Rating | IP68 |
Explosion-proof Mark | Exd IIC T6 Gb |
Explosion-proof Certificate No. | CNEx16.029 |
System Diagram | Please refer to the attached system diagram. |
User manuals, video tutorials, and on-site training (upon request)
Safety is our top priority. The system is equipped with multiple sensors. If the temperature inside the protective cover exceeds 50℃, the compressed air pressure drops below 0.2 MPa, the cooling water flow falls below 0.2 m³/h, or if there is a sudden power outage, the system will automatically and rapidly retract the probe (with a 550mm stroke) out of the furnace to prevent severe heat damage to the camera and lens.
No. The front end of the probe features a special spiral air curtain design. This creates a continuous, high-velocity barrier of clean air that effectively blows dust, soot, and corrosive gases away from the sapphire lens, ensuring a clear and uninterrupted visual feed without the need for frequent manual cleaning.
Absolutely. The system is designed for seamless plant integration. Operators in the central control room can remotely control the camera menu, adjust the lens aperture, and monitor the camera feed. Furthermore, all critical alarm signals (such as high temperature or low pressure) can be directly accessed and integrated into your existing DCS software.
Yes. The system is built to rigorous safety standards. It holds an Explosion-proof Certificate (CNEx16.029) with an Ex-Mark of Exd IIC T6 Gb, and features an IP68 protection rating. The dual-lens separation high-temperature protective cover ensures true explosion-proof performance, making it safe for use in volatile environments.
The system is suitable for furnaces with a wall thickness of ≤ 500mm. During the installation phase, we will provide detailed wall opening (brick drawing) dimensions and installation diagrams. The control console can be customized to your preference, available in wall-mounted, desk-mounted, or cabinet-mounted configurations.
The system requires both compressed air and cooling water to maintain the internal operating temperature (≤ 80℃ for the retraction device).
- Air: Inlet pressure of 0.2 ~ 0.7 MPa, minimum flow of 0.3 m³/min.
- Water: Inlet pressure of 0.1 ~ 0.7 MPa, minimum flow of 0.8 m³/h. Both utilities must be at an inlet temperature of ≤ 35℃.




Whatsapp: +86-15312392280
E-mail: hedy@lmgd-cctv.com